AC-LN Low Noise Air Cooler

From NZ$ 923.30

The AC-LN air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air.

The coolers with an axial fan can be used in the return line as well as in the bypass flow. The wide range of accessories and optional versions mean that the coolers can be adapted flexibly to various applications.

Moreover, the optimisation of the air flow of the cooler is possible by using a more efficient axial fan and a variety of housing modifications. As a result, the AC-LN series 2-14 is especially efficient and quiet.

We can also use the cooler in the bypass flow by attaching a boost pump.

On the other hand, an additional filter enables continuous filtration of the medium; the cooler can, therefore, be connected as required.

Features:
  • A large product range
  • Also, a large cooling performance range
  • And a modular design
Application Field:

This cooler applies to systems with high cooling requirements, such as:

  • Hydraulic systems
  • Lubrication systems
  • Gears
  • Motors
  • Generators
  • Converters
  • Machine tools
This is our AC-LN Low Noise Air Cooler - Australian Market Range:
Part number Description Fan RPM @ 50 Hz Recommended Oil flow range Heat Rejection @ ΔT=40°C (ISO VG46 oil) Noise level (1m distance)
3957556 AC-LN2S/1.0/F/A/1/IBP3 1500 2 to 25 L/min 1.3 to 4.5 kW 64 dB(A)
4028964 AC-LN3S/1.0/F/A/1/IBP3 1500 4 to 60 L/min 3.1 to 8.0 kW 66 dB(A)
4028963 AC-LN3H/1.0/F/A/1/IBP3 3000 4 to 60 L/min 4.2 to 12.0 kW 85 dB(A)
3952094 AC-LN4L/1.0/F/A/1/IBP3 1000 10 to 50 L/min 6.2 to 10.5 kW 63 dB(A)
4028975 AC-LN4S/1.0/F/A/1/IBP3 1500 10 to 70 L/min 7.8 to 14.1 kW 72 dB(A)
4028976 AC-LN5L/1.0/F/A/1/IBP3 1000 10 to 80 L/min 8.0 to 15.0 kW 65 dB(A)
4028978 AC-LN5S/1.0/F/A/1/IBP3 1500 10 to 100 L/min 8.9 to 20.6 kW 75 dB(A)
4028979 AC-LN6L/1.0/F/A/1/IBP3 1000 20 to 140 L/min 12.1 to 20.1 kW 67 dB(A)
4014476 AC-LN6S/1.0/F/A/1/IBP3 1500 20 to 140 L/min 15.2 to 25.6 kW 77 dB(A)
4028980 AC-LN7L/1.0/F/A/1/IBP3 1000 25 to 180 L/min 19.6 to 35.1 kW 76 dB(A)
4028981 AC-LN7S/1.0/F/A/1/IBP3 1500 25 to 220 L/min 21.7 to 49.3 kW 84 dB(A)
3808454 AC-LN8L/1.0/F/B/1/IBP3 1000 30 to 200 L/min 22.2 to 40.2 kW 68 dB(A)
3766846 AC-LN8S/1.0/F/B/1/IBP3 1500 30 to 260 L/min 26.0 to 56.2 kW 79 dB(A)
3803773 AC-LN9L/1.0/F/B/1/IBP3 1000 40 to 280 L/min 31.6 to 56.6 kW 67 dB(A)
3808488 AC-LN9S/1.0/F/B/1/IBP3 1500 40 to 300 L/min 37.0 to 69.7 kW 80 dB(A)
3805063 AC-LN10L/1.0/F/B/1/IBP3 1000 50 to 360 L/min 44.9 to 82.9 kW 71 dB(A)
3805097 AC-LN10S/1.0/F/B/1/IBP3 1500 50 to 360 L/min 50.6 to 104.5 kW 77 dB(A)
3800896 AC-LN11L/1.0/F/B/1/IBP3 1000 60 to 400 L/min 56.5 to 111.0 kW 75 dB(A)
3800897 AC-LN11S/1.0/F/B/1/IBP3 1500 60 to 540 L/min 62.7 to 143.0 kW 81 dB(A)
3805098 AC-LN12L/1.0/F/B/1/IBP3 1000 80 to 700 L/min 76.7 to 165.5 kW 74 dB(A)
3805161 AC-LN12S/1.0/F/B/1/IBP3 1500 80 to 780 L/min 86.7 to 212.5 kW 80 dB(A)
3805162 AC-LN14L/1.0/F/B/1/IBP3 1000 100 to 840 L/min 98.4 to 223.6 kW 78 dB(A)
3805205 AC-LN14S/1.0/F/B/1/IBP3 1500 100 to 840 L/min 110.3 to 272.3 kW 84 dB(A)
HYDAC's SVC cooling system for mine site

HYDAC's SVC cooling system for mine site

Oil cooler for a compressor in New South Wales

Oil cooler for a compressor in New South Wales

Improving reliability and system efficiency in a mine site in Queensland

Improving reliability and system efficiency in a mine site in Queensland

Shell tube heat exchanger replacement in a synthetic rutile plant in WA

Shell tube heat exchanger replacement in a synthetic rutile plant in WA

Cooling system for a gold mine’s tower mill gearbox

Cooling system for a gold mine’s tower mill gearbox

Please see below part numbers

Grouped product items
Part# Description List Price Availability Qty
Loading...

Please wait...

Please contact the store to confirm stock availability near you

FAQs

  • Can the AC-LN air cooler series be used in all areas where either oil or water-glycol is cooled with air?

    Yes, the AC-LN air cooler series can be used in all areas where either oil or water-glycol is cooled with air.

    What are the AC-LN air cooler series’ main features?

    AC-LN air cooler series’ main features are a large product and cooling performance range and a modular design.

    Can AC-LN air coolers with an axial fan be used in return line as well as in bypass flow?
    Yes, AC-LN air coolers with an axial fan be used in return line as well as in bypass flow.
    Can the AC-LN air cooler be adapted flexibly to various applications?

    Yes, a wide range of AC-LN air cooler accessories and optional versions mean that coolers can be adapted flexibly to various applications.

    Can the AC-LN air cooler’s air flow be optimised?

    Yes, the optimisation of the AC-LN air cooler’s air flow is possible by using a more efficient axial impeller and a variety of housing modifications. As a result, the AC-LN series 2-14 is especially efficient and quiet.

    Can the AC-LN air cooler be used in bypass flow by attaching a boost pump?

    Yes, the AC-LN air cooler can be used in bypass flow by attaching a boost pump.

    Does the AC-LN air cooler enable continuous filtration of the medium?

    Yes, an additional AC-LN air cooler enables continuous filtration of the medium.

    What are AC-LN air cooler application fields?

    AC-LN air cooler applications include hydraulic and lubrication systems to gears, motors, generators, converters, and machine tools.